Antokolsky Tower Ibn Gabirol Tel Aviv
16 בOctober 2018
Smart Towers, Ramat Gan
17 בOctober 2018

Ahimeir Tower, Tel Aviv



key facts


Pinui Binui project (evacuation and reconstruction) – demolishing an old building and constructing two floors for commerce: 16 floors + a partial floor, and 66 residential units in the exclusive tower. Every three floors are rotated at an angle is relation to the three floors beneath them.

Shading and wind analysis was conducted for the project to make sure that there are no strong winds on the upper floors in transitional seasons, and that no shadow is cast on the pool in the summer and in transitional seasons.

Sun exposure analysis ensured that the roof of the tower is exposed to direct sunlight, allowing the installation of solar water tanks for efficient water heating.

18

Floors


16

Residential units


Project details:

Location: Ramat Aviv neighborhood C, Tel Aviv

Architect: Yashar Architects

Client: Aviv Company

WAWA operations: Green building standard certification, thermal consulting, computational wind analysis CFD, shading analysis, natural light analysis

Construction category: Residential tower incorporating commerce

Challenges:

The Ahimeir project is situated in a relatively open area, and its ground floor is designed to include a swimming pool. One of the concerns raised was about winds, due to the tower’s proximity to the Mediterranean Sea and due to its height.

Among other factors examined, it was critical to make sure that the swimming pool area would provide an environment with climatic comfort – that the pool is not shaded, but that strong winds would not develop due to the project’s geographical and physical attributes.

Testing was conducted throughout the entire process using simulations that assessed the casting of shadows, natural light, and wind development in all areas of the project.

Added value:

Shading analysis, computational wind analysis, and sun exposure analysis facilitated the optimal utilization of the microclimate and natural light in the design of the tower.

In order to ensure the correct location and design of the swimming pool, we conducted wind analysis to determine the probability of the development of strong winds at the complex. We confirmed that strong winds would not develop in the summer and in transitional seasons.

Testing determined that all residential units on the various sides of the building would receive good, appropriate exposure to direct sunlight in order to enable a healthy, pleasant living environment.

The typical floors include wind-facing windows in roughly 75% of the residential units. This application enables optimal cross ventilation in most areas of the project and comfort ventilation in most of the rooms in the residential units.

FOR MORE INFORMATION - PLEASE CONTACT US

x
סייען נגישות
הגדלת גופן
הקטנת גופן
גופן קריא
גווני אפור
גווני מונוכרום
איפוס צבעים
הקטנת תצוגה
הגדלת תצוגה
איפוס תצוגה

אתר מונגש

אנו רואים חשיבות עליונה בהנגשת אתר האינטרנט שלנו לאנשים עם מוגבלויות, וכך לאפשר לכלל האוכלוסיה להשתמש באתרנו בקלות ובנוחות. באתר זה בוצעו מגוון פעולות להנגשת האתר, הכוללות בין השאר התקנת רכיב נגישות ייעודי.

סייגי נגישות

למרות מאמצנו להנגיש את כלל הדפים באתר באופן מלא, יתכן ויתגלו חלקים באתר שאינם נגישים. במידה ואינם מסוגלים לגלוש באתר באופן אופטימלי, אנה צרו איתנו קשר

רכיב נגישות

באתר זה הותקן רכיב נגישות מתקדם, מבית all internet - בניית אתרים.רכיב זה מסייע בהנגשת האתר עבור אנשים בעלי מוגבלויות.